Home > ADSS OCSP Monitor > Alerts

Alerts

ADSS OCSP Monitor can be configured to send email and/or SMS alerts to selected operator(s) when these events occur:
System operators who will receive these alerts can be configured here as well.

The configuration items are as follows:

Item Description
Failed to compose OCSP request
When enabled, an alert is sent whenever service failed to compute OCSP response.
Target OCSP responders unavailable 
When enabled, an alert is sent whenever service failed to access OCSP responder.
Failed to verify OCSP response
When enabled, an alert is sent whenever service failed to verify OCSP response.
Unexpected result returned for test case When enabled, an alert is sent whenever a test case failed and result is not according to expectation.
Internal error occurred (Reason: database not accessible etc)
When enabled, the ADSS OCSP Monitor sends an email alert when an internal error has occurred (e.g. database is not accessible).
Unable to use log signing Key at auto-archiving time
When enabled, ADSS OCSP Monitor sends an email alert when it is unable to use the Log Signing Key at auto-archiving time. Note that Log Signing Key is configured in Global Settings >> System Certificates section.
When archiving is performed
When enabled, ADSS OCSP Monitor sends an email alert whenever auto-archiving is performed.
>> <<
These buttons are used to select and deselect system operators to whom alerts would be sent.

Changes made in this page are saved by the Save button.