Alerts
ADSS OCSP Monitor can be configured to send email and/or SMS alerts to selected operator(s) when these events occur:
- Failed to compose OCSP request
- Target OCSP responders unavailable
- Failed to verify OCSP response
- Unexpected result returned for test case
- If an internal error has occurred
- If the OCSP Monitor service is unable to use log signing key at auto-archiving time
- When archiving has successfully completed
System operators who will receive these alerts can be configured here as well.
The configuration items are as follows:
Items |
Description |
Failed to compose OCSP request |
When enabled, an alert is sent whenever service failed to compute OCSP response. |
Target OCSP responders unavailable |
When enabled, an alert is sent whenever service failed to access OCSP responder. |
Failed to verify OCSP response |
When enabled, an alert is sent whenever service failed to verify OCSP response. |
Unexpected result returned for test case |
When enabled, an alert is sent whenever a test case failed and result is not according to expectation. |
Internal error occurred (Reason: database not accessible etc) |
When enabled, the ADSS OCSP Monitor sends an email alert when an internal error has occurred (e.g. database is not accessible). |
Unable to use log signing Key at auto-archiving time |
When enabled, ADSS OCSP Monitor sends an email alert when it is unable to use the Log Signing Key at auto-archiving time. Note: The Log Signing Key is configured in Global Settings > System Certificates module. |
When archiving is performed |
When enabled, ADSS OCSP Monitor sends an email alert whenever auto-archiving is performed. |
>> and << |
These buttons are used to select and deselect system operators to whom alerts would be sent. |
Changes made in this page are saved by the Save button.